One Raffles Place

T2 Floor plan
BUILDING SPECIFICATIONS
Green Mark Certification
Platinum
 
Overall size
Approximately 350,000 sq ft nett leaseable
area of Prime Grade A office space
 
No. of office floors
33 floors (Storey 4th to 38th)
 
Typical floor area (NLA)
Approximately 11,000 sq ft
 
Core-to-window depth
16.45m
 
Raised floor
Raised floor in 600x600 mm module pressed steel top, lightweight concrete infill. Raised floor height L5-38 - 150mm
 
Floor loading
3.5kN/sqm and 7.5kN/sqm for compactus loading along 1m width of core wall area
 
Curtain wall
Full height glass. Unitised aluminium system with double glazed low E heat strengthened glass
 
Total no. of car parking spaces
326 lots, full ERP Electronic Parking System
 
Toilets
Male (2 cubicles and 3 urinals) and Female
(3 cubicles), 1 Handicap and 1 Executive with shower
 
Pantry
1 common pantry on each floor
 
Air-conditioning and mechanical ventilation
- Central chilled water air-conditioning system
- Office floor - chilled water AHU c/w ducting and diffusers
- Main office lift lobby - chilled water AHU c/w ducting and diffusers
- Mechanical ventilation to staircase, smoke stop and fire fighting lobbies and toilets
 
Security system
- 24 hour CCTV monitoring at all main entrances and exits
- Card Access Control for turnstile at 1st storey lift lobbies, controlled access for staircases.
 
Fire protection
Automatic sprinkler, wet riser system, hosereel system and fire alarm system
 
Lighting
Average 500 Lux for office at 0.8AFFL T5 flourescent light, metal reflector, high frequency ballast
 
Electricity supply and electricity loads
Dual feed for 22kV incoming power supply. Office - 40 Amp three phase neutral isolator normal source, 20 Amp three phase neutral isolator emergency source. (DB and switch socket outlets by tenant)
 
Computing earthing
Earth bar provided on every office floor
 
Standby generator
33% of tenants' normal load
 
Spare riser space
Space in electrical riser from 4th to 7th storey for tenant cabling to tenant genset, subject to availability
 
Space reserved for tenants own generator set
Provided above 4th storey link bridge
 
Telecommunication
Telecommunication distribution block terminal provided at landlord's common riser (telephone points by tenant) & SCV cable ready
 
Other features
Large column-free floorplates, high security features: bomb blast protected & penthouse office